Replacing Desiccants
Four desiccant bags are placed inside the device to remove moisture. If the Internal Humidity stream exceeds a configurable threshold, an alert is sent to designated user group(s).
Note: The electronics in the Wavelet Ex™ are fully potted, so no desiccants need to be replaced in that model.
Important Notes
Ensure the top enclosure is dry.
During battery replacement or external power use, wipe the upper enclosure with a soft cloth.
In humid environments, check and dry the enclosure periodically.
Dispose of desiccants in regular waste.
Prerequisites
Torque screwdriver
Work in a clean, dry environment
Ensure your hands and the device are completely dry
Protect against static discharge
Replacement Steps
Place the device face down on a dry, stable surface with connectors pointing downward.

Partially unscrew the six screws on the back panel until you can lift it off (keep screws in place).
Tip: Loosen manually before using an electric screwdriver.

Remove the back panel and place it flat-side down.
Warning: Do not remove the rubber gasket in the panel rim; it’s thin and not glued.

Move the ON/OFF switch on the interface board to OFF.

Replace the old desiccants with new ones.

Move the ON/OFF switch back to ON.
Device performs a 10-minute calibration, then resumes normal mode.

Reinstall the back panel. Ensure:
The battery cable is neatly arranged and not pinched.
The rubber gasket is in place. Missing gaskets void water/dust damage coverage.

Tighten all six screws to 1 Nm torque.
Do not over-tighten to avoid stripping screw threads.